Used with typical output information such as Bill of Quantities or Bill of Materials from engineering tools. The CESK Bill of Quantities (BoQ) are a perfect match for cost estimators who want to efficiently translate detailed quantities into an accurate cost estimate, including costs for materials and labor. The CESK BoQ dataset is developed to work in close harmony with the output from engineering design tools, such as BoQs and MTOs. Not only does the CESK BoQs allow for direct estimating of a wide range of disciplines, materials and sizes, it also incorporates information that is normally not included in a BoQ/MTO. For example, a piping MTO can be directly translated into a cost estimate of the piping materials included in that MTO, but also adds the related handling, supporting, testing and installation to your estimate. This means the estimator needs less time to prepare a complete cost estimate, leaving more time for optimizing and improving the quality of the overall estimate. The CESK BoQs are also a perfect solution for estimating based on pipe specs, where the defined piping specifications can easily be matched to the corresponding BoQ rates. Choose from the tabs below to view additional information about the CESK Bill of Quantities Dataset. Although piping is an important part of the CESK BoQ data, BoQ rates are also available for numerous other disciplines, such as electrical, instrumentation and steel structures. These can be found in the overview below. At the BOQ level, the civil knowledgebase is composed of different pre-defined structures. The composition of each structure includes the subcomponents: concrete, steel (rebar), and form work. The quantity of each subcomponent associated with each structure depends on its dimension and industry standards derived relations. When determining the quantities of the components at the BOQ level, the only information needed is the volume of concrete for the predefined structure. BoQ-rates for equipment installation, including un-loading for Columns, Compressors, Heat exchangers, Pumps and Motors, Vessels, Skid units and packaged units. If you want to know more about CESK bill of quantities and CESK data, please feel free to contact us.CESK Bill of Quantities
CESK Bill of Quantities
Additional Information
Basin
Beams
Block
Column footing
Columns
Octagon
Plint
Pour
Slabs
Tank wall
Pipe racks
Earth cable
Armoured 6-30kV
1,5 - 400 mm2
Supply and Install Above ground
Earth cable ZH
Armoured Flex
1-37x
Supply and Install Under ground
LV cable
EMC
Class 1, 2 & 5
LV cable EPR
Flex EMC
ea 16-95mm2
LV cable ZH
Lead Armour
LV cable ZH 30/60
Non Arm
LV cable ZH 90
Wiring
MV cable
Conduit
HDG
50-1000mm
Installed with support
Ladderrack
PVC
Installed without support
Tray
SS316
Wire mesh tray
Heat trace infrastructure
Elbow
-45 - 200 degrees
Self regulating cable
Flange
1" - 24"
Instrument
10 - 150mm insulation
Pipe
Pipe support
Pump
Tee
Valve
Zone 2-3
3x-8x
Installed on support
M20-M32
PG16 - PG21
Floodlight
Closed
18-250W
Fastened on wall or ceiling
Industrial
Louvred
Mounted on mast
Office
Waterproof
Mounted on support
Zone 1
Zone 2
1,000 - 400,000
Install and unload
Centrifugal
0-300,000
Install and unload
Reciprocating
Install and unload
1,000 - 125,000
Install and unload
0-300,000
Install and unload
0-50,000
Install and unload
Bubble cap tray
0 - 5,500 mm
Install and unload
Chimney tray bolted
Chimney tray sealwelded
Demister package
Demister part of package
Distributor tray
Holddown grid
Liquid distributor
Random packing
Sieve tray
Structured packing
Support grid
Tray manway
Valve tray
Vapor distributor
Horizontal
0 - 400,000
Install and unload
Vertical
Elbow
D=1/2" - 48"
Flange cap
DN 15 - 1200
Pipe
Valve cap
Cold type (ALU)
Elbow
D=1/2" - 48"
(Rem Insu + Sheet)
Cold type (SS)
End cap
DN 15 - 1200
(Rem+Re-use Insu)
Hot type (ALU)
Equipment
(Re-use Insu + Sheet)
Hot type (SS)
Flange cap
(Re-use Sheet + New Insu)
Pipe
Thk = 30 - 140mm
(New Insu + New Sheet)
Reducer
(Rem & Re-use Insu + Sheet)
Tee
(Rem & New Insu+ Rem & Re-use Sheet)
Valve cap
(Rem & New Insu+ Rem & New Sheet)
-20 up to +120 °C, CS
(m2)
D=1/2" - 48"
Painting + Blasting [SA2.5]+ X% Touch-up
>+120 up to +200 °C, CS
Bend 45
DN 15 - 1200
>+200 up to +450 °C, CS
Bend 90
Spec.Cap
-20 up to +120 °C, SS
Elbow
>+120 up to +200 °C, SS
Flange
Flange cap
Pipe
Reducer
Tee
Valve
Valve cap
Weld (field)
Alloy20
Bellows
Cold Insulated
150-3000#
Install ISBL
CS
Bending pipe
Hot Insulated
D= 1/2-48"
Install OSBL
CS GALV
Bleed Ring
Not protected
Sch=5(S) - 160(S)
Install Pipe rack
Duplex
Bushing
Painted
Hasteloy
Cap
Painted + Cold Insulated
LTCS
Coupling
Painted + Hot Insulated
SS304
Cross
SS316
Elbolet
Titanium
Elbow
Flange
Hose
Lateral
Latrolet
Level Gauges
Nipolet
Nipple
Pipe
Plug
Quick coupling
Reducer Insert
Reducer
Sight Glass
Sockolet
Spacer
Spectacle blind
Steam trap
Strainer, Basket
Strainer, T
Strainer, Y
Stubend
Swage, Concentric
Swage, Eccentric
Tee
Test Blank
Threadolet
Union
Valve, Ball (Manual operated)
Valve, Butterfly (Manual operated)
Valve, Check
Valve, Diaphragm
Valve, ESD
Valve, Gate (Manual operated)
Valve, Globe (Manual operated)
Valve, Other
Valve, Relief
Weldolet
1.4306
Cap
Cold Insulated
DN 15 - 1200mm
Install ISBL
1.4404
Elbolet
Hot Insulated
PN10 - 400
Install OSBL
CS
Elbow
Not protected
Wth = 1,4 - 65 mm
Install Pipe rack
LTCS
Flange
Painted
Latrolet
Painted + Cold Insulated
Nipolet
Painted + Hot Insulated
Pipe
Reducer
Sockolet
Tee
Threadolet
Valve, Ball (Manual operated)
Valve, Butterfly (Manual operated)
Valve, Check
Valve, Gate (Manual operated)
Valve, Globe (Manual operated)
Weldolet
GRP
Elbow 45 deg
Not protected
D = 20 - 500mm
Electric weld socket connection
HDPE/PE
Elbow 90 deg
Hot insulated
D=1/2" - 20"
Glue connection
PVC
Flange
PN10 - 16
Laminate connection
Pipe
Wth 2-29,4
Mirror weld
Reducer
Stress resistant rubber connection
Tee
GRP
Elbow 45 deg
Not protected
D = 20 - 500mm
Electric weld socket connection
HDPE/PE
Elbow 90 deg
Hot insulated
D=1/2" - 20"
Glue connection
PVC
Flange
PN10 - 16
Laminate connection
Pipe
Wth 2-29,4
Mirror weld
Reducer
Stress resistant rubber connection
Tee
LV cable
Armoured
LV cable EPR
Armoured Flex
LV cable ZH
EMC
LV cable ZH 30/60
Flex EMC
LV cable ZH 90
Lead Armour
Non Arm
Wiring
Conduit
HDG
50-1000mm
Installed with support
Ladderrack
PVC
Installed without support
Tray
SS316
Wire mesh tray
Ball valve
Elecric actuated
1-24"
Installed with support
Butterfly valve
Pneumatic actuated
150-600#
Installed without support
Eccentric plug valve
Globe valve
Membrane valve
Segment ball valve
Indicator
1-10"
Installed with support
Switch
Installed without support
Transmitter
On concrete floor
100-600mm
On steel floor
On unpaved floor
On pipe
EEXe
Polyester
6-120 terminals
Installed on support
SS316
Indicator
Installed with support
Switch
Installed without support
Transmitter radar
Transmitter remote seal
Transmitter ultrasonic
Controller
Installed with support
Diaphragm gauge
Installed without support
Diaphragm transmitter
Differential diaphragm gauge
Differential diaphragm transmitter
Differential gauge
Differential transmitter
Gauge
Indicator
Switch
Transmitter
Controller
Installed with support
Element
Installed without support
Gauge
Indicator
Switch
Transmitter
Transmitter RTD
Pipe racks
Civil
Electrical
Cables
TypesSub typesRangesInstallation methods
Cable support material
TypesSub typesRangesInstallation methods
Heat tracing
TypesSub typesRanges
Junction boxes
TypesRangesInstallation methods
Lighting
TypesSub typesRangesInstallation methods
Equipment Installation
Column
RangesInstallation locations
Compressor
Sub typesRangesInstallation locations
Heat exchanger
RangesInstallation locations
Package unit
RangesInstallation locations
Pump + Motor
RangesInstallation locations
Trays & Internals
Sub typesRangesInstallation locations
Vessel
Sub typesRangesInstallation locations
Piping, Insulation, Painting, Coating & Wrapping
Coating and wrapping
Fittings, valves and pipesInstallation locations
Insulation
MaterialsFittings, valves and pipesRangesInstallation locations
Painting
MaterialsFittings, valves and pipesRangesInstallation locations
Piping (ASME)
MaterialsFittings, valves and pipesProtection typesRangesInstallation locations
Piping (DIN)
MaterialsFittings, valves and pipesProtection typesRangesInstallation locations
Piping (Plastic)
MaterialsFittings, valves and pipesProtection typesRangesInstallation locations
Piping (Plastic)
MaterialsFittings, valves and pipesProtection typesRangesInstallation locations
Instrumentation
Cables
TypesSub types
Cable support material
TypesSub typesRangesInstallation methods
Control valves
TypesSub typesRangesInstallation methods
Flow instrument
TypesRangesInstallation methods
Instrument supports
TypesRanges
Junction boxes
TypesSub typesRangesInstallation methods
Level instrument
TypesInstallation methods
Pressure instrument
TypesInstallation methods
Temperature instrument
TypesInstallation methods
Structural
Types